| Name | Read|Write | Available Value | Factory Value | Unit | Remark
|
| DioList | Read
| Dio1.1,Dio1.2,Dio1.3,Dio1.4 | | | List of available DIO devices
|
| Dio1Data | Read|Write
| 0~15 | 15 | | Dio data value
bit0: Dio1.1 data value
bit1: Dio1.2 data value
bit2: Dio1.3 data value
bit3: Dio1.4 data value
|
| Dio1.1Data | Read|Write
| 0,1 | 1 | | Dio1.1 data value
0: Low level
1: High level
|
| Dio1.1Mode | Read|Write
| DigitalInput,DigitalOutput,Pwm | DigitalInput | | Dio1.1 mode
DigitalInput: Dio1.1 used for level input, pulse counting, etc
DigitalOutput: Dio1.1 used for level output
Pwm: Dio1.1 used for pulse width modulation output
|
| Dio1.2Data | Read|Write
| 0,1 | 1 | | Dio1.2 data value
0: Low level
1: High level
|
| Dio1.2Mode | Read|Write
| DigitalInput,DigitalOutput,Pwm | DigitalInput | | Dio1.2 mode
DigitalInput: Dio1.2 used for level input, pulse counting, etc
DigitalOutput: Dio1.2 used for level output
Pwm: Dio1.2 used for pulse width modulation output
|
| Dio1.3Data | Read|Write
| 0,1 | 1 | | Dio1.3 data value
0: Low level
1: High level
|
| Dio1.3Mode | Read|Write
| DigitalInput,DigitalOutput | DigitalInput | | Dio1.3 mode
DigitalInput: Dio1.3 used for level input
DigitalOutput: Dio1.3 used for level output
|
| Dio1.4Data | Read|Write
| 0,1 | 1 | | Dio1.4 data value
0: Low level
1: High level
|
| Dio1.4Mode | Read|Write
| DigitalInput,DigitalOutput | DigitalInput | | Dio1.4 mode
DigitalInput: Dio1.4 used for level input
DigitalOutput: Dio1.4 used for level output
|